I’m a retired electrical engineer with extensive experience in embedded control and software development - I know what I’m talking about here. Then it will immediately reconnect but this is a lot of effort and could be fixed in the controller firmware. It randomly looses the network connection and will not always reconnect without a hardware reset which requires removing AC power and disconnecting the genset battery. At least on the 20RESA - just the oil temperature and the temperature is not even close to accurate.ĥ. You cannot see the output current of the generator.Ĥ. If you remotely start the generator, that becomes the new exercise start time and resets the exercise interval.ģ. You have to get the key and go to the generator. You cannot set or reset the exercise time from OnCue.
![kohler oncue software kohler oncue software](http://northpointpowersystems.com/images/products/r.jpeg)
You have to get the key and go to the generator.Ģ. You cannot set the controller time from OnCue. it’s lacking several key capabilities that would make it so much more useful.ġ.
#Kohler oncue software generator#
RetiredEE - Useful but lacking in several key capabilitiesĪ must-have if you have a Koehler generator but.
#Kohler oncue software update#
This update includes various bug fixes and performance improvements. The controller’s “Next Exercise” time will be displayed in the exercise card (if a time is set). Ability to change Next Exercise Time on controller via app (inside of exercise card details) Ability to change controller Date/Time via app(under Generator Settings) If your controller is model RDC 2.4 and has installed firmware 2.0.5 or greater the following features are accessible in OnCue Plus This release includes bug fixes and performance improvements
#Kohler oncue software manuals#
I've been through the manuals and don't see a way to force the controller to request a DHCP IP address from the router.OnCue Plus Customer Service, Editor Notes: OnCue Plus Version 2.1.3 09 June 2021 In the meantime, I was wondering if anyone here had heard of this issue, or know what else I can try. Sent an email to my dealer with all the details of my troubleshooting and they are contacting Kohler. That should mean that its connected and transmitting, but still nothing. Also can see the port light up on my network switch, meaning there is a signal on that cable. When I plugged the cable back in to the bottom of the controller, both lights on the network plug light up. Switch it on and it tests the wires 1-8 and checks for shorts. One piece plugs into one end of the cable, another piece to the other end.
![kohler oncue software kohler oncue software](http://ecx.images-amazon.com/images/I/31mgQLIOXTL.jpg)
Being a computer geek, I have a tool to check network cables. Used another known-good cable, but still no go. I tried turning it off, waited a while, turned it back on, wait, but still doesn't connect.įirst thing I thought of was the network cable. Nothing there has changed and all other devices connect just fine and get an assigned IP. After a lot of head scratching, I discovered that the controller was not connected to my network. I logged into OnCue Plus and it shows "Not Connected". I normally get the notification emails at the beginning and end of the exercise. Everything has been working fine until the weekly test cycle ran on Wednesday. Also have the RXT transfer switch and OnCue Plus. I have a Kohler 20RESA generator with the RDC2 controller, manufacture date 7/21/15, installed about a week later.